This section is included in your selections.
The urban standards applicable to proposed development within the districts established by Section 2 (Zoning Map) are as follows.
Proposed redevelopment of the site shall comply with the standards provided by Section 4.10 (Urban Standards Table) for the T5 transect zone, except where alternative standards are authorized through conditional use permit approval or design review. Minor changes in existing structures may conform with the current development pattern of the site in terms of building placement, setbacks and heights.
Proposed redevelopment shall comply with standards established by the review authority through the conditional use permit process or design review.
Proposed redevelopment of the site shall comply with the standards provided by Section 4.10 (Urban Standards Table) for the T6 transect zone, except where alternative standards are authorized through conditional use permit approval or design review. Minor changes in existing structures may conform with the current development pattern of the site in terms of building placement, setbacks and heights.
Proposed redevelopment of the site shall comply with the standards provided by Section 4.10 (Urban Standards Table) for the T5 transect zone, except as follows:
Building Placement - “Edge Yards” permitted
Percent Building Frontage Required - No minimum
Parking Location - Parking in “1st Layer ” permitted
T1 NATURAL ZONE
T2 RURAL ZONE
T3 SUB-URBAN ZONE
T4 GENERAL URBAN ZONE
T5 URBAN CENTER ZONE
T6 URBAN CORE ZONE
SD SPECIAL DISTRICT
a. BLOCK SIZE
Block Perimeter
2,000 lf. max.
1,700 ft. max.
1,700 ft. max.
Refer to Section 4.20
2,400 lf. max. for blocks with internal parking
2,000 lf. max for blocks with internal parking
2,000 lf. max for blocks with internal parking
b. THOROUGHFARES (See Section 5 for further Standards)
Highway (HW)
not permitted
not permitted
not permitted
Refer to Section 4.20
Road (RD)
not permitted
not permitted
not permitted
Street (ST)
permitted
permitted
permitted
permitted
not permitted
Drive (DR)
permitted
permitted
permitted
permitted
permitted by warrant
Avenue (AV)
permitted
permitted
permitted
permitted
permitted by warrant
Commercial Street or Avenue
permitted
permitted
permitted
permitted
permitted
permitted
Boulevard (BV)
permitted by warrant
permitted by warrant
permitted by warrant
Rear Alley (RA)
permitted
permitted
permitted
permitted
permitted
permitted
Rear Lane (RL)
permitted
permitted
not permitted
not permitted
c. CIVIC SPACES (See Section 4.50 For Graphic Summary and further Standards)
Regional Park
not permitted
not permitted
not permitted
Refer to Section 4.20
Sports Complex
not permitted
not permitted
not permitted
Community Park
permitted by warrant
not permitted
not permitted
Greenway
permitted by warrant
not permitted
not permitted
Neighborhood Green
permitted
permitted
permitted
permitted
not permitted
Neighborhood Square
permitted
permitted
permitted
permitted
permitted
permitted
Plaza
permitted
permitted
permitted
permitted
permitted
permitted
Pocket Plaza
permitted
permitted
permitted
permitted
permitted
permitted
Pocket Park
permitted
permitted
permitted by warrant
not permitted
Playground
permitted
permitted
permitted
permitted
permitted by warrant
Community Garden
permitted
permitted
permitted by warrant
permitted by warrant
d. LOT OCCUPATION
Lot Area
4,000 sq. ft avg.
None
None
Refer to Section 4.20
Lot coverage
60% max.
None
None
e. Build-to Line - PRINCIPAL BUILDING
Front
not applicable
not applicable
0 ft. min
Refer to Section 4.20
f. SETBACKS - PRINCIPAL BUILDING
Front
0 ft. min. 15 ft. max.
0 ft. min. 10 ft. max.
not applicable
Refer to Section 4.20
Side
5 ft. min. 30 ft. max.
0 ft. min. 10 ft. max.
0 ft. min. 10 ft. max.
Rear - No Alley
20 ft. min.
5 ft. min.
0 ft. min.
Rear - Alley
0 ft. min.
0 ft. min.
0 ft. min.
g. SETBACKS - OUTBUILDING
Front Setback
20 ft.
40 ft.
not applicable
Refer to Section 4.20
Side Setback
0 ft.
0 ft.
not applicable
Rear - No Alley
5 ft. min.
5 ft. min.
not applicable
Rear - Alley
0 ft. min.
0 ft. min.
not applicable
h. % BLDG. FRONTAGE REQ'D
Principal Frontage
50% min.
75% min.
90% min.
Refer to Section 4.20
Secondary Frontage
30% min.
35% min.
50% min.
i. BUILDING PLACEMENT (See Section 4.30 for Graphic Summary and Further Standards)
Edgeyard
permitted
permitted
prohibited
prohibited
Refer to Section 4.20
Sideyard
permitted
permitted
permitted
permitted
prohibited
Rearyard
permitted
permitted
permitted
permitted
permitted
permitted
Courtyard
permitted
permitted
permitted
permitted
permitted
permitted
j. ALLOWED BUILDING TYPES (See Section 4.80 For Graphic Summary and further Standards)
Carriage House
permitted
permitted
not permitted
not permitted
Refer to Section 4.20
Detached House: Estate
not permitted
not permitted
not permitted
Detached House: Village
permitted
permitted
not permitted
not permitted
Detached House: Cottage
permitted
permitted
not permitted
not permitted
Bungalow Court
permitted
permitted
not permitted
not permitted
Duplex
permitted
permitted
not permitted
not permitted
Townhouse
permitted
permitted
permitted
permitted
not permitted
Mansion Apartment
permitted
permitted
not permitted
not permitted
Apartment House
permitted
permitted
permitted
permitted
not permitted
Courtyard Building
permitted
permitted
permitted
permitted
not permitted
Main Street Building
permitted
permitted
permitted
permitted
permitted
permitted
Mid-Rise
not permitted
permitted
permitted
permitted
permitted
k. PRIVATE FRONTAGES (See Section 4.40 For Graphic Summary and further Standards)
Common Yard
not permitted
not permitted
not permitted
Refer to Section 4.20
Porch, Projecting or Engaged
permitted
permitted
not permitted
not permitted
Stoop
permitted
permitted
permitted
permitted
not permitted
Forecourt
permitted
permitted
permitted
permitted
not permitted
Dooryard
permitted
permitted
permitted
permitted
not permitted
Shopfront
permitted
permitted
permitted
permitted
permitted
permitted
Terrace
permitted
permitted
permitted
permitted
permited
Gallery
permitted
permitted
permitted
permitted
permitted
permitted
Arcade
permitted
permitted
permitted
permitted
permitted
permitted
Parking Lot (See 4.40.150)
not permitted
permitted
permitted
permitted
permitted
l. BUILDING HEIGHT
Principal Building
3 stories max.
4 stories max. 2 min. (See max. 2 min. (See 4.20.010 for height bonus information)
6 stories max. 3 min.
Refer to Section 4.20
Outbuilding
2 stories max.
2 stories max.
not applicable
m. GROUND FLOOR CEILING
Lodging or Residential Uses (excluding Live/Work)
10' min.
10' min.
10' min.
Refer to Section 4.20
All other uses
12' min.
14' min.
14' min.
n. GROUND FLOOR SPACE DEPTH
Principal Frontage
30' min.
30' min.
30' min.
Refer to Section 4.20
Secondary Frontage
30' min.
30' min.
30' min.
o. DISTANCE BETWEEN ENTRIES
To Ground-Floor Uses
not applicable
50' max.
50' max.
Refer to Section 4.20
To Upper-Floor Uses
not applicable
100' max.
100' max.
p. PARKING LOCATION
1st Layer
prohibited
prohibited
prohibited
Refer to Section 4.20
2nd Layer
prohibited
prohibited
prohibited
3rd Layer
permitted
permitted
permitted
permitted
permitted
permitted
q. PARKING REQUIREMENTS
Residential (including Live/Work)
1 space per market rate unit
.5 space per affordable unit
1 space per market rate unit
.5 space per affordable unit
1 space per market rate unit
.5 space per affordable unit
Refer to Section 4.20
Lodging
1 space per room
1 space per room
1 space per room
All other uses
2 spaces per 1000sq. ft
2 spaces per 1000sq. ft
2 spaces per 1000sq. ft
r. BUILDING FUNCTION (See Section 3 )